INCO Hydromet Facility
Argentia, NL    

Trade: Electrical, instrumentation

Description: Pennecon Energy provided module fabrication support and its expertise for this Voisey’s Bay Nickel Company project.




Global Santa Fe Glomar Grand Banks Maintenance and Refit
Bay Bulls, NL    

Trade: Piping, electrical, structural

Description: Pennecon was responsible for drilling maintenance and refits for this project.




TransOcean Henry Goodrich Inspection Survey and Refit (mechanical, hydraulic, structural and electrical
Bull Arm, NL    

Trade: Coatings, inspection, electrical, structural, instrumentation, piping, hydraulic, mechanical overhaul and testing, NDT testing and 3500 HP thruster motor electrical, anode replacement, top drive overhauls and five year inspection

Description: Owned by TransOcean Canada Co., this project required Pennecon's expertise for exterior work, anode replacement, top drive overhauls, motor rewinding, painting, mechanical inspection, NDT testing, and 3500 HP motor electrical, mechanical overhaul, and testing.  A five year inspection was also required.




Terra Nova Turnaround
Rotterdam, The Netherlands       

Trade: Hydraulic

Description: This major project for Pennecon Energy had numerous phases. On the voyage to Rotterdam, we did a complete removal of main transfer deck using clamshell cutters. Once we reached The Netherlands, we prepared a flushing procedure for a complete offshore flushing of the water injection pump lubrication system, then performed a complete re-certification of all pressure vessels aboard the Terra Nova FPSO.




Abitibi Consolidated
Grand Falls, NL

Trade: Upgrades, refits, installations

Description: In this 2002 project for Abitibi Consolidated, we installed a hydraulic governor system during a refit of the Grand Falls Mill.  During the refit, we also completed chemical cleaning, hydrotesting, and hot oil flushing of the hydraulic governor piping system.




Newfoundland Power
Cape Broyle, NL

Trade: Fabrication, installation, construction

Description: Pennecon Energy Technical Services was contracted to refurbish a generating unit at Cape Broyle in 2006.  The scope of this project included the refurbishment of the generator and rotor windings with a process called CO2 or Dry-Ice Cleaning and the mechanical repair of the gates.  In addition to this scope of work Pennecon Energy Technical Services was also engaged to perform the Dry-Ice cleaning of the NF Power generating unit at Pierre's Brook near Witless Bay.  Pennecon Energy Technical Services is one of the only companies in Newfoundland and Labrador that has this equipment locally and provides the cleaning process to external customers.




Noble Drilling Canada Ltd.
Hibernia Platform, Offshore NL (1998-present)

Trade: Rotating equipment, maintenance and commissioning

Description: Owned by Noble Drilling (Canada) Ltd., Ozark Services provided rotating equipment maintenance and commissioning.




Rattling Brook Rewind
Rattling Brook, NL

Trade: Power generation services

Description: This project required power generation services for owner, General Electric Power Systems.